The inverter is the least conspicuous component of a photovoltaic system – and one of the most important. Solar modules generate direct current; the household and the grid need alternating current. The inverter handles this conversion and controls the entire system: it monitors the yield, optimises the performance, and ensures grid compliance. This page explains the types, the correct sizing, and what you should look for in the quote.

Key points at a glance
- Inverters convert the direct current of the solar modules into usable alternating current.
- The choice affects yield, monitoring, storage capability and expandability.
- String inverters are the most common type in classic residential systems.
- Hybrid inverters are relevant if battery storage is planned – today or later.
- Microinverters or power optimisers can be useful where there is shading.
- Costs must always be considered in the context of the entire PV quote.
- As of 04.11.2026
- Sources at the end of the article
What does an inverter do in a photovoltaic system?
The modules on the roof supply direct current (DC). Your appliances and the public grid operate with alternating current (AC). The inverter sits in between and performs four tasks:
- Converting: Direct current becomes grid-compliant alternating current.
- Optimising: Using so-called MPP tracking, the inverter continuously draws the maximum possible power from the modules.
- Monitoring: Yield, consumption and errors are recorded and usually made visible via an app or portal.
- Protecting: In the event of grid disturbances, the inverter automatically disconnects from the grid – a safety requirement of the grid operator.
If a central inverter or string inverter fails, the affected system or part of the system is usually shut down. In contrast, with microinverters, a failure may be limited to individual modules. Quality and appropriate design therefore pay off over the entire service life.
What types of PV inverters are there?
For residential systems, four solutions are the main options:
| Type | Typical application | Advantage | Disadvantage |
|---|---|---|---|
| String inverter | Conventional roof system | Proven, efficient, good value for money | Less flexible with partial shading |
| Hybrid inverter | PV with battery storage | Storage can be integrated directly, one device for both | Not always necessary, higher price |
| Microinverter | Individual modules, small systems | Good in case of shading, module-by-module monitoring | Higher complexity and costs per kWp |
| Inverter with power optimisers | Complex, partially shaded roofs | Optimisation per module possible | Additional components on the roof |
For most single-family homes with an unshaded roof, a string inverter is the right solution. With chimneys, dormers or trees casting shadows, it is worth looking at optimisers or microinverters – and those planning a storage system should check the hybrid inverter.
Which inverter suits shade and storage?
Two questions matter: does shade fall on your roof, and do you want to add battery storage later? The overview shows how the four types compare on these points.
| Type | Purpose | With shading | With storage | Strength | Weakness |
|---|---|---|---|---|---|
| String inverter | one device for several strings of modules, usually in the basement or garage | shade can reduce the output of a whole string; bypass diodes, splitting the strings and multiple inputs soften the effect | can be retrofitted with a separate battery inverter | little technology on the roof, easily accessible | if the only device fails, the whole system stops |
| Hybrid inverter | String inverter with a battery connection | as with a string inverter | can connect approved storage, also later on; check the battery and any activation costs | one device for solar power and storage | more expensive if a battery is never added |
| Microinverter | a small device directly under each module or pair of modules | each device controls its modules separately, which reduces losses from shade | storage is usually retrofitted on the AC side | Yield and faults visible per module | many devices on the roof; repairs need access to the roof |
| Power optimiser | small optimisers per module, plus a central inverter | each module is controlled separately, which reduces losses from shade | depends on the central inverter; also possible with a hybrid device | depending on the system, can be used only where shade falls | additional components on the roof |
Separate control reduces the additional losses when modules get different amounts of light. The shaded modules themselves still produce less electricity. With little shade, the extra devices’ own losses can even cancel out the gain.
An example from practice: on a south-facing roof, the chimney casts shade on two out of twenty modules in the afternoon. How much this slows down the other modules depends on the wiring and on the inverter’s shade management. A suitable split of the strings, an inverter with good shade management or optimisers that suit the system can help. A separate string needs enough modules for the voltage to be sufficient for the inverter. So have the options calculated for you in the quotes. A roof without shade needs none of this.
How is an inverter sized correctly?
The inverter’s output must match the system – but not on a 1:1 basis. Because modules rarely sustain their rated power in everyday use, the inverter is often sized slightly smaller than the total module capacity. The appropriate sizing depends, however, on roof orientation, shading, system size, self-consumption and grid connection.
What goes into the sizing:
- Roof orientation: East-west systems distribute production over the day; the inverter can be relatively smaller than with a purely south-facing system.
- Shading: Partially shaded areas speak in favour of optimisers or multiple MPP trackers.
- Battery storage: Planned or conceivable? Then clarify hybrid capability or retrofitability.
- Later expansion: Plan in reserve capacity if there is still space on the roof.
- Wallbox and heat pump: Influence self-consumption and energy management – the inverter should be able to communicate with the planned system.
- Grid connection: The grid operator specifies how much power may be fed in; larger systems sometimes require a feed-in limit or ripple control.
Working out the specific design is the specialist installer’s job – a good quote sets it out clearly.
What does the ratio of module output to inverter mean?
Specialist installers compare the output of all modules in kilowatt peak (kWp) with the power the inverter can deliver to the house (kW). A worked example: modules totalling 10 kWp on an 8 kW inverter give a ratio of 1.25. On sunny middays, the inverter may then cap the peak. How often this happens and whether the design makes economic sense depends on orientation and location, among other things. So ask for both values in the quote, with a short explanation of why the specialist installer chose this ratio.
What does an inverter cost?
The inverter typically accounts for a single-digit to low double-digit percentage of the total investment. Isolated device prices say little, as costs depend on:
- Output and number of MPP trackers
- Manufacturer and quality segment
- Hybrid capability (storage connection)
- Monitoring scope
- Installation effort and placement
More important than the unit price: the quote should clearly state which model is used – with output, warranty and compatibility. Do not compare device prices, but complete packages with the same scope of services. You can read how the total costs of a system add up on the page What does a photovoltaic system cost.
What will a later replacement cost?
Many inverters run for longer than 15 years. Even so, expect to replace the device once during the system’s 25-year lifetime. The Swiss Federal Office of Energy uses these amounts:
| System size | Replacement of the inverter |
|---|---|
| 10 kW | CHF 3’000 |
| 100 kW | CHF 9’000 |
Source: Swiss Federal Office of Energy, Technology Monitoring Photovoltaics (Bern University of Applied Sciences and SUPSI), table 13, version 1.2 of 09.01.2026
Adjustments to the installation may come on top, such as new cables or a different location for the device. For a single-family home with 10 kW, this means around CHF 120 per year spread over 25 years. This amount belongs in your profitability calculation.
Can you connect an inverter yourself?
No. Only a specialist installer with an installation licence from the Federal Inspectorate for Heavy Current Installations (ESTI) may connect the inverter and link the system to the house wiring. Non-professionals may only mount the modules themselves and plug together their ready-made connectors on the frame. Cables running beyond the frame and connections that are not plug-ready, such as those at the inverter, belong in the hands of professionals. This also applies if they are still outside the building.
For you, this means: have a faulty inverter replaced by a specialist installer too. Your system may also only feed electricity into the grid once the grid operator has agreed. After handover, you arrange an independent acceptance inspection within six months. You give the resulting safety certificate to the grid operator. If a company with a restricted licence built the DC part, an accredited inspection body is needed for this.
How do inverters and battery storage work together?
If you are planning a storage system, there are two basic concepts:
- DC-coupled (hybrid inverter): The battery is connected directly to the inverter. This means solar power can be stored without first flowing into the home's AC grid. There are still losses; what matters is the efficiency of the whole system. This works well when the system and the battery are planned together.
- AC-coupled: The storage system has its own battery inverter and is connected to the home’s electrical system. More flexible for retrofitting, as the existing inverter can stay.
For both: Backup power or emergency power is not automatically included. Anyone who wants to continue having electricity during a power outage must plan for this explicitly and request a quote. Details on storage size and costs: Photovoltaic system with battery storage.
How does monitoring support the operation of a PV system?
Modern inverters provide the data basis for operation:
- Yield monitoring in real time and over time
- App or web portal for an overview
- Fault detection with notification – important so that outages do not go unnoticed for weeks
- Consumption data, if a smart meter is connected
- Self-consumption optimisation by controlling a wallbox, boiler or heat pump
When reviewing the quote, ask what the monitoring covers and whether it incurs ongoing costs.
What should you look for in the quote?
Before you request a quote, have this information ready so that the subsidy and cost-effectiveness can be checked properly:
- Manufacturer and model specified?
- Is the capacity appropriately sized for the PV system?
- Is hybrid capability needed – today or later?
- Is storage compatibility documented?
- Does it include a backup power function or not?
- Monitoring included (app/portal, costs)?
- Warranty and service conditions?
- Expandability (second string, larger system)?
- Grid operator requirements taken into account?
With this information, the specialist installer can assess the subsidy, self-consumption and technical design much more reliably.
Three points are often overlooked in quotes:
- Output of modules and inverter: Both values should be listed separately so that you can follow the ratio.
- Warranty in detail: How long does it last, and does it cover only the device or also labour and call-out? With microinverters and optimisers, it also matters who pays for access to the roof.
- Notifications and inspection: Who registers the system with the grid operator, and who orders the acceptance inspection?
If you ask several specialist installers, you quickly see who explains their design openly: Compare quotes.
What mistakes are often made with inverters?
Avoid these mistakes by taking a close look at the quote:
- Selecting the inverter based on price alone.
- Planning a storage system for later but not choosing an inverter that is hybrid-capable or can be retrofitted.
- Ignoring shading and doing without optimisers where they would be needed.
- Assuming backup power is included when it is not.
- Accepting quotes without a clear model designation.
- Not considering later expansion (wallbox, heat pump, more modules).
solar-guide.ch recommends: Settle the storage question before you choose the inverter. If you think a battery storage system is possible in the coming years, choose a hybrid inverter or clarify whether AC retrofitting is possible – this is cheaper than replacing the device later. And insist on a clear model designation in every quote: without manufacturer, type and warranty details, quotes cannot be compared reliably.
What is ultimately decisive for the inverter?
The inverter helps determine the yield, safety, storage capability, and comfort of a photovoltaic system. For standard roofs, the string inverter is proven; in cases of shading, optimisers or microinverters help; and those planning a storage system should consider the hybrid inverter. The appropriate design belongs in the hands of the specialist installer – and the clear model specification in every quote.
Are you planning a photovoltaic system and would like to know which components make sense? Through solar-guide.ch, you can submit your request free of charge and without obligation. Your request will be forwarded to a maximum of three suitable specialist installers from your region.
Which modules exist and what they deliver: Solar modules compared.
Frequently asked questions and answers
What does an inverter do in photovoltaics?
It converts the direct current from the modules into grid-compliant alternating current, continuously optimises performance, monitors the system, and automatically disconnects it from the grid during grid disturbances.
What types of inverters are there?
String inverters (standard for residential systems), hybrid inverters (with battery storage connection), microinverters (per module) and systems with power optimisers (for partially shaded roofs).
What is a hybrid inverter?
An inverter with an integrated connection for battery storage. PV power and storage run through a single device – efficient when the system and storage are planned together.
How long does an inverter last?
Often more than 15 years: according to the Swiss Federal Office of Energy, over 65% of devices still had no defect in their 15th year of operation. The office expects one replacement during the system’s 25-year service life. So plan for it; warranty extensions can be worthwhile.
Is backup power automatically included?
No. Without a special backup power or emergency power function, the system shuts down in the event of a grid failure. Anyone who wants backup power must explicitly plan for it and request a quote.
What should I look for in the quote?
Look for a clear model designation with output, warranty, storage compatibility and monitoring scope – and make sure the design suits the roof, consumption and planned extensions. Details: Photovoltaic system quote.
What is a microinverter?
A small inverter that sits directly under one module or a pair of modules. Each device controls its modules separately. This reduces losses on complex or partly shaded roofs. On the other hand, there are many devices on the roof, and storage is usually retrofitted on the AC side.
Is a hybrid inverter worth it without storage?
If you think you might add battery storage in the next few years, often yes: approved storage can then be connected without a second device. Ask which batteries the device supports and whether there are extra costs for connecting or activating it later. If you are sure you will not add storage, a string inverter is usually enough.
How much does it cost to replace the inverter?
The Swiss Federal Office of Energy assumes CHF 3’000 for a 10 kW system and CHF 9’000 for 100 kW. Adjustments to the installation may come on top. The office assumes one replacement over 25 years of operation.
Is a layperson allowed to connect the inverter?
No. Connecting and replacing it belong in the hands of a specialist installer with an ESTI installation licence. Non-professionals may only mount modules and their ready-made connectors on the frame.
Average: 4.7 out of 5 stars (12 ratings)